Devices & Protocols
KALA designs communication paths between CASC or CURIOTEC weighing equipment and PLCs, computers, remote displays, printers, SCADA platforms and business software. The correct protocol depends on distance, noise environment, update rate, device count and existing infrastructure.
Protocol Selection Guide
| Protocol | Max Distance | Devices | Typical Use |
|---|---|---|---|
| RS-485 / Modbus RTU | 1,200 m | Up to 32 | Indicator → PLC, multi-drop cell bus |
| CAN / ISN | 500 m | Up to 127 | CURIOTEC cell bus, fast diagnostics |
| RS-232 | 15 m | Point-to-point | Indicator → PC, legacy printer |
| Ethernet / TCP | 100 m (switch) | Network | SCADA, MES, cloud gateway |
Physical Layer Commissioning
Before analysing frames, KALA verifies cable topology, polarity, shield bonding, reference ground, termination resistors, biasing, connectors and surge protection. We then confirm baud rate, parity, stop bits, addressing and command timing — building a documented baseline for the integration team.
From Protocol to Usable Data
Read stable weight, status and zero state from indicator
Monitor individual digital load cells via CASC KDB-D or CURIOTEC RPWB-D bus
Send weight data to PLC, SCADA, MES or PC applications
Drive remote displays and ticket printers over RS-232 or RS-485
Log diagnostic values (raw counts, corner gains, overload flags) for preventive maintenance
CASC vs CURIOTEC Communication
▶ CASC (KDB-D / DS8)
- Proprietary RS-485 cell bus with individual addressing
- DS8 indicator exposes Modbus RTU for PLC integration
- Corner data, raw counts and fault flags per cell
- Standard baud: 9600 / 19200 bps
▶ CURIOTEC (RPWB-D / ISN)
- CAN-based ISN protocol with real-time diagnostics
- RS-485 option available on RPWB-D and NDSB-D
- Fast corner balance and overload detection
- Gateway to Modbus / Ethernet on request
Related Technical Articles
⚡
KALA’s engineering approach
KALA can capture and interpret frames when integration information is limited, then document a repeatable interface for the automation team — whether the project uses CASC DS8 and KDB-D cells or a CURIOTEC platform.
Talk to KALA
Need RS-485, Modbus, CAN or Ethernet integration for your weighing system? Let’s talk.